{"id":1349,"date":"2025-04-17T10:14:18","date_gmt":"2025-04-17T08:14:18","guid":{"rendered":"https:\/\/www.se-elektronic.com\/?post_type=product&#038;p=1349"},"modified":"2026-02-05T12:05:20","modified_gmt":"2026-02-05T11:05:20","slug":"automation-station-e-ddc-e-device-e-ddc-a43","status":"publish","type":"product","link":"https:\/\/www.se-elektronic.com\/en\/product\/automation-station-e-ddc-e-device-e-ddc-a43\/","title":{"rendered":"Automation station E-DDC, E-device"},"content":{"rendered":"<p>Automation station with integrated operator panel, successor unit for IPC-A4.x.<\/p>\n<ul>\n<li><span dir=\"ltr\" role=\"presentation\">Central unit with display, pushbuttons, LEDs<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Interfaces: 1\u00d7 Ethernet, 1\u00d7 USB, 2\u00d7 RS485 <\/span><span dir=\"ltr\" role=\"presentation\">(1x A-bus, 1x B-bus), 1x C-bus<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Emulation of the program functionality of an IPC-A4.2<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Additional E-DDC functionality<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Compatible for A- and B-bus (channel 1 fixed on <\/span><span dir=\"ltr\" role=\"presentation\">A-bus, channel 2 fixed on B-bus)<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Front frame made of plastic (ABS) in aluminum gray <\/span><span dir=\"ltr\" role=\"presentation\">included in delivery<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Multi-line display for operator navigation and <\/span><span dir=\"ltr\" role=\"presentation\">system-specific data such as setpoints, current values, <\/span><span dir=\"ltr\" role=\"presentation\">status messages and clock routines<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Control keyboard for menu navigation<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">12 freely programmable control elements, each <\/span><span dir=\"ltr\" role=\"presentation\">consisting of a labelable push button and a 3-color <\/span><span dir=\"ltr\" role=\"presentation\">addressable LED<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Any assignment of LEDs and keys for system functions, <\/span><span dir=\"ltr\" role=\"presentation\">e.g. LEDs for operating, fault and other status messages, <\/span><span dir=\"ltr\" role=\"presentation\">buttons for switching control functions on and off<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Freely definable fault and operating message texts as <\/span><span dir=\"ltr\" role=\"presentation\">well as recipe texts (instructions for fault <\/span><span dir=\"ltr\" role=\"presentation\">rectification) for each individual fault message<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Individual and collective acknowledgement option of <\/span><span dir=\"ltr\" role=\"presentation\">faults, event recording with date and time<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">1\u00d7 Ethernet interface for network connection and <\/span><span dir=\"ltr\" role=\"presentation\">IP communication for BACnet, webservices, Modbus <\/span><span dir=\"ltr\" role=\"presentation\">TCP (Client\/Server), webconfiguration, programming, <\/span><span dir=\"ltr\" role=\"presentation\">service, FTP &#8230;<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">1\u00d7 USB service interface (type B) for diagnostics, <\/span><span dir=\"ltr\" role=\"presentation\">parameterization and maintenance, webserver <\/span><span dir=\"ltr\" role=\"presentation\">functionality<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">1\u00d7 C-bus interface for 22 C-bus participants per line<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">SD flash card for trend data, application, CAD data, <\/span><span dir=\"ltr\" role=\"presentation\">languages, firmware &#8230;<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">NVRAM for non-volatile data (data retention via battery <\/span><span dir=\"ltr\" role=\"presentation\">CR 1632)<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">1\u00d7 real time clock (RTC) with automatic summer and <\/span><span dir=\"ltr\" role=\"presentation\">winter time changeover<\/span><\/li>\n<\/ul>\n<h3>Software webconfiguration<\/h3>\n<ul>\n<li><span dir=\"ltr\" role=\"presentation\">Comfortable password-protected web interface with <\/span><span dir=\"ltr\" role=\"presentation\">user-dependent access<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Configuration: Device, network, bus, modem, routing, <\/span><span dir=\"ltr\" role=\"presentation\">BACnet settings &#8230;<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">System: Diagnostic options for BACnet objects, <\/span><span dir=\"ltr\" role=\"presentation\">communication, backup &amp; restore, firmware update &#8230;<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Project Viewer: Display (and modification) of configured <\/span><span dir=\"ltr\" role=\"presentation\">BACnet objects as operating data, alarms and trend <\/span><span dir=\"ltr\" role=\"presentation\">recordings &#8230;<\/span><\/li>\n<\/ul>\n<h3>Further software functions<\/h3>\n<ul>\n<li><span dir=\"ltr\" role=\"presentation\">Routing of IP and BACnet networks<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Access control via a user administration (roles and <\/span><span dir=\"ltr\" role=\"presentation\">rights)<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Compatible to the BACnet standard ISO 16484-5:2012, <\/span><span dir=\"ltr\" role=\"presentation\">Rev. 12, and additionally from firmware version 03.08.08 <\/span><span dir=\"ltr\" role=\"presentation\">also BACnet standard ISO 16484-5:2017, Rev. 15. <\/span><br role=\"presentation\" \/><span dir=\"ltr\" role=\"presentation\">Details see PICS list and AMEV test certificate<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Processing of up to 2.000 BACnet objects<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Sending BACnet notifications (alarms or messages) <\/span><span dir=\"ltr\" role=\"presentation\">by e-mail or SMS<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Direct online programming via PC with graphic <\/span><span dir=\"ltr\" role=\"presentation\">programming interface, module library and macro <\/span><span dir=\"ltr\" role=\"presentation\">functions for compact controls, 65.536 program <\/span><span dir=\"ltr\" role=\"presentation\">lines, sample applications are available for individual <\/span><span dir=\"ltr\" role=\"presentation\">adaptation<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">32.767 analog and digital data points each (internal), as <\/span><span dir=\"ltr\" role=\"presentation\">well as further data points (external) for communication <\/span><span dir=\"ltr\" role=\"presentation\">with the RS485 bus, the IO modules and the field bus<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Geographical sun position calculation of the relevant <\/span><span dir=\"ltr\" role=\"presentation\">sun angles, as well as the times of sunrise and sunset<\/span><\/li>\n<\/ul>\n<h3>Options, software packages (activation code with registered access via SE homepage)<\/h3>\n<ul>\n<li><span dir=\"ltr\" role=\"presentation\">BACnet G 01 03 10<\/span><\/li>\n<li>Modbus G 01 03 20 (Modbus Client)<\/li>\n<\/ul>\n<h3>Certificates<\/h3>\n<ul>\n<li>BACnet standard ISO 16484-5:2017, Rev. 15<\/li>\n<li><span dir=\"ltr\" role=\"presentation\">AMEV test certificate according to DIN EN ISO 16484-5 <\/span><span dir=\"ltr\" role=\"presentation\">with AMEV profile AS-B AMEV BACnet 2017 (automation <\/span><span dir=\"ltr\" role=\"presentation\">station with extended equipment)<\/span><\/li>\n<\/ul>\n<p><span dir=\"ltr\" role=\"presentation\">Robust metal housing with plastic frame for front installation, front color: silver.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Automation station with integrated operator panel, successor unit for IPC-A4.x.<\/p>\n","protected":false},"featured_media":1351,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[21],"product_tag":[],"class_list":{"0":"post-1349","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-automation-stations-ddc","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/product\/1349","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/media\/1351"}],"wp:attachment":[{"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/media?parent=1349"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/product_brand?post=1349"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/product_cat?post=1349"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/product_tag?post=1349"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}