{"id":1332,"date":"2025-04-15T16:02:18","date_gmt":"2025-04-15T14:02:18","guid":{"rendered":"https:\/\/www.se-elektronic.com\/?post_type=product&#038;p=1332"},"modified":"2026-02-05T11:52:35","modified_gmt":"2026-02-05T10:52:35","slug":"automation-station-e-ddc-e-device-e-ddc12","status":"publish","type":"product","link":"https:\/\/www.se-elektronic.com\/en\/product\/automation-station-e-ddc-e-device-e-ddc12\/","title":{"rendered":"Automation station E-DDC, E-device"},"content":{"rendered":"<p><span dir=\"ltr\" role=\"presentation\">Freely programmable modular DDC unit for regulating, controlling, monitoring and optimising systems <\/span><span dir=\"ltr\" role=\"presentation\">for building automation. Realisation of simple HVAC solutions through to complex requirements and interdisciplinary <\/span><span dir=\"ltr\" role=\"presentation\">cross-trade communication.<\/span><\/p>\n<p><span dir=\"ltr\" role=\"presentation\">Significant increase in performance and the number of active participants thanks to the new F-bus technology.<\/span><\/p>\n<ul>\n<li><span dir=\"ltr\" role=\"presentation\">2\u00d7 Ethernet interface for web services, BACnet IP, Mo<\/span><span dir=\"ltr\" role=\"presentation\">dbus TCP (Client\/Server), web configuration, program<\/span><span dir=\"ltr\" role=\"presentation\">ming, service, FTP &#8230; and connection to touch panel <\/span><span dir=\"ltr\" role=\"presentation\">(e.g. HMI-WEB7)<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">2\u00d7 RS485 interface (2-wire) for communication via <\/span><span dir=\"ltr\" role=\"presentation\">BACnet MS\/TP, Modbus RTU (Client\/Server) and SE <\/span><span dir=\"ltr\" role=\"presentation\">standard A-, B-, E-bus<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">1\u00d7 USB service interface (type B) for diagnostics, <\/span><span dir=\"ltr\" role=\"presentation\">parameterisation and maintenance, web server <\/span><span dir=\"ltr\" role=\"presentation\">functionality<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">1\u00d7 C- \/ F-bus line for up to 23 (C-bus) \/ 32 (F-bus) <\/span><span dir=\"ltr\" role=\"presentation\">devices<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">1\u00d7 F-bus line for up to 32 F-bus devices<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">2\u00d7 RS485 interface (Modbus master via F-bus) <\/span><span dir=\"ltr\" role=\"presentation\">(activation of \u2018Modbus master\u2019 software package <\/span><span dir=\"ltr\" role=\"presentation\">required)<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">18\u00d7 universal inputs, use is parameterizable<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">16\u00d7 digital inputs<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">2\u00d7 digital inputs with counter function<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">8\u00d7 digital inputs also as DO function<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">8\u00d7 analog outputs<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">8\u00d7 digital outputs &#8211; relay contact normally open (NO): <\/span><span dir=\"ltr\" role=\"presentation\">each max. AC 250 V<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">4\u00d7 digital outputs &#8211; relay contact (changeover contact): <\/span><span dir=\"ltr\" role=\"presentation\">each max. AC 250 V<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">SDHC flash card for trend data, application, CAD data, <\/span><span dir=\"ltr\" role=\"presentation\">languages, firmware &#8230;<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">NVRAM for non-volatile data (data retention via buffer <\/span><span dir=\"ltr\" role=\"presentation\">battery)<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">1\u00d7 real time clock (RTC) with automatic summer and <\/span><span dir=\"ltr\" role=\"presentation\">winter time changeover<\/span><\/li>\n<\/ul>\n<h3>Software webconfiguration<\/h3>\n<ul>\n<li><span dir=\"ltr\" role=\"presentation\">Comfortable password-protected web interface with <\/span><span dir=\"ltr\" role=\"presentation\">user-dependent access<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Configuration: Device, network, bus, modem, routing, BACnet settings &#8230;<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">System: Diagnostic options for BACnet objects, communication, backup &amp; restore, firmware update &#8230;<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Project Viewer: Display (and modification) of configured BACnet objects as operating data, alarms and trend recordings &#8230;<br \/>\n<\/span><\/li>\n<\/ul>\n<h3>Further software functions<\/h3>\n<ul>\n<li><span dir=\"ltr\" role=\"presentation\">Routing of IP and BACnet networks<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Access control via a user administration (roles and rights)<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Compatible to the BACnet standard ISO 16484-5:2017, Rev. 15. Details see PICS list and AMEV test certificate<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Processing of up to 2.000 BACnet objects<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Sending BACnet notifications (alarms or messages)by e-mail or SMS<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Direct online programming via PC with graphic programming interface, module library and macro functions for compact controls, 128.000 program lines, sample applications are available for individual <br role=\"presentation\" \/>adaptation<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">32.767 analog and digital data points each (internal), as well as further data points (external) for communication with the RS485 bus, the IO modules and the field bus<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Software package: BACnet G 01 03 10 included<\/span><\/li>\n<\/ul>\n<h3>Options, software packages (activation code with registered access via SE homepage)<\/h3>\n<ul>\n<li>Modbus G 01 03 20 (Modbus Client)<\/li>\n<\/ul>\n<p><span dir=\"ltr\" role=\"presentation\">Robust metal housing, industrial design for top hat rail mounting.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p><span dir=\"ltr\" role=\"presentation\">Freely programmable modular DDC unit for regulating, controlling, monitoring and optimising systems for building automation.<\/span><\/p>\n","protected":false},"featured_media":1333,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[21],"product_tag":[],"class_list":{"0":"post-1332","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-automation-stations-ddc","8":"first","9":"instock","10":"featured","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/product\/1332","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/media\/1333"}],"wp:attachment":[{"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/media?parent=1332"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/product_brand?post=1332"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/product_cat?post=1332"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/product_tag?post=1332"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}