{"id":11200,"date":"2026-01-28T11:03:43","date_gmt":"2026-01-28T10:03:43","guid":{"rendered":"https:\/\/www.se-elektronic.com\/?post_type=product&#038;p=11200"},"modified":"2026-02-06T07:18:15","modified_gmt":"2026-02-06T06:18:15","slug":"automation-station-e-ddc2-5-e-device","status":"publish","type":"product","link":"https:\/\/www.se-elektronic.com\/en\/product\/automation-station-e-ddc2-5-e-device\/","title":{"rendered":"Automation station E-DDC2.5, E-device"},"content":{"rendered":"<p><span dir=\"ltr\" role=\"presentation\">Certified native BACnet Building Controller (device profile B-BC) according to the BACnet standard ISO 16484-5:2017, Rev. 15. <\/span><span dir=\"ltr\" role=\"presentation\">Freely programmable modular DDC unit for regulation, control, monitoring and optimization of building automation systems. <\/span><span dir=\"ltr\" role=\"presentation\">Realization of simple HVAC solutions up to complex requirements and cross-trade communication with router functionality. <\/span><span dir=\"ltr\" role=\"presentation\">A high degree of planning reliability and interoperability is provided by the standardized and widely used communication <\/span><span dir=\"ltr\" role=\"presentation\">protocols, such as BACnet or Modbus. <\/span><span dir=\"ltr\" role=\"presentation\">Significant increase in performance and the number of active participants due to the new F-bus technology<\/span><\/p>\n<ul>\n<li><span dir=\"ltr\" role=\"presentation\">2\u00d7 Ethernet interface for network connection and IP <\/span><span dir=\"ltr\" role=\"presentation\">communication for BACnet, webservices, Modbus TCP <\/span><span dir=\"ltr\" role=\"presentation\">(Client\/Server), webconfiguration, programming, service, <\/span><span dir=\"ltr\" role=\"presentation\">FTP &#8230;<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">2\u00d7 RS485 interface (2-wire) for communication via <\/span><span dir=\"ltr\" role=\"presentation\">BACnet MS\/TP (with router funktion), Modbus <\/span><span dir=\"ltr\" role=\"presentation\">RTU (Client\/Server) and SE-Standard A-, B-, E-bus<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">1\u00d7 USB service interface (type B) for diagnostics, <\/span><span dir=\"ltr\" role=\"presentation\">parameterization and maintenance, webserver <\/span><span dir=\"ltr\" role=\"presentation\">functionality<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">2\u00d7 C-\/F-Bus interface, optionally for 22 C-bus or 32 <\/span><span dir=\"ltr\" role=\"presentation\">F-bus participants per line<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">2\u00d7 digital outputs &#8211; relay contact (changeover contact): <\/span><span dir=\"ltr\" role=\"presentation\">each max. AC 24 V, 0.01 V \/ DC 30 V, 0,01 V<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">SDHC flash card for trend data, application, CAD data, <\/span><span dir=\"ltr\" role=\"presentation\">languages, firmware &#8230;<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">NVRAM for non-volatile data (data retention via buffer <\/span><span dir=\"ltr\" role=\"presentation\">battery)<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">1\u00d7 real time clock (RTC) with automatic summer and <\/span><span dir=\"ltr\" role=\"presentation\">winter time changeover<\/span><\/li>\n<\/ul>\n<h3>Software webconfiguration<\/h3>\n<ul>\n<li><span dir=\"ltr\" role=\"presentation\">Comfortable password-protected web interface with <\/span><span dir=\"ltr\" role=\"presentation\">user-dependent access<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Configuration: Device, network, bus, modem, routing, <\/span><span dir=\"ltr\" role=\"presentation\">BACnet settings &#8230;<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">System: Diagnostic options for BACnet objects, <\/span><span dir=\"ltr\" role=\"presentation\">communication, backup &amp; restore, firmware update &#8230;<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Project Viewer: Display (and modification) of configured <\/span><span dir=\"ltr\" role=\"presentation\">BACnet objects as operating data, alarms and trend <\/span><span dir=\"ltr\" role=\"presentation\">recordings &#8230;\u00a0<\/span><\/li>\n<\/ul>\n<h3>Further software functions<\/h3>\n<ul>\n<li>Routing of IP and BACnet networks<\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Access control via a user administration (roles and <\/span><span dir=\"ltr\" role=\"presentation\">rights)<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Compatible to the BACnet standard ISO 16484-5:2017, <\/span><span dir=\"ltr\" role=\"presentation\">Rev. 15. Details see PICS list and AMEV test certificate<\/span><\/li>\n<li>Processing of up to 2.000 BACnet objects<\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Sending BACnet notifications (alarms or messages) <\/span><span dir=\"ltr\" role=\"presentation\">by e-mail or SMS<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">Direct online programming via PC with graphic <\/span><span dir=\"ltr\" role=\"presentation\">programming interface, module library and macro functions for compact controls, 65.520 program lines, sample applications are available for individual adaptation<\/span><\/li>\n<li><span dir=\"ltr\" role=\"presentation\">32.767 analog and digital data points each (internal), as <\/span><span dir=\"ltr\" role=\"presentation\">well as further data points (external) for communication <\/span><span dir=\"ltr\" role=\"presentation\">with the RS485 bus, the IO modules and the field bus<\/span><\/li>\n<li>Software package: BACnet G 01 03 10 included<\/li>\n<\/ul>\n<h3>Options, software packages (activation code with registered access via SE homepage)<\/h3>\n<ul>\n<li>Modbus G 01 03 20 (Modbus-Client)<\/li>\n<\/ul>\n<h3>Certificates<\/h3>\n<ul>\n<li>BACnet standard ISO 16484-5:2017, Rev. 15<\/li>\n<li><span dir=\"ltr\" role=\"presentation\">AMEV test certificate according to DIN EN ISO 16484-5 <\/span><span dir=\"ltr\" role=\"presentation\">with AMEV profile AS-B AMEV BACnet 2017 (automation <\/span><span dir=\"ltr\" role=\"presentation\">station with extended equipment)<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>Robust metal housing, industrial design for top hat rail mounting.<\/p>\n","protected":false},"excerpt":{"rendered":"<p><span dir=\"ltr\" role=\"presentation\">Certified native BACnet Building Controller (device profile B-BC) according to the BACnet standard ISO 16484-5:2017, Rev. 15. <\/span><span dir=\"ltr\" role=\"presentation\">Freely programmable modular DDC unit for regulation, control, monitoring and optimization of building automation systems<\/span><\/p>\n","protected":false},"featured_media":11277,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[21],"product_tag":[],"class_list":{"0":"post-11200","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-automation-stations-ddc","8":"first","9":"instock","10":"shipping-taxable","11":"purchasable","12":"product-type-simple"},"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/product\/11200","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/media\/11277"}],"wp:attachment":[{"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/media?parent=11200"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/product_brand?post=11200"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/product_cat?post=11200"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.se-elektronic.com\/en\/wp-json\/wp\/v2\/product_tag?post=11200"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}